Etc CEM3 v1.5.1 Manual do Utilizador Página 31

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 76
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 30
2 System Reference 25
Modified Linear (Mod-Linear)
A modified linear curve reduces the voltage change at low control levels for better
performance in low-wattage fixtures.
Square Law (Square)
At low control levels, much of a traditional incandescent fixture’s light output is in the
invisible infrared spectrum. This results in poor visible response to low control levels. A
square law curve applies a multiple derived from the square root of the control level (with
full output equal to 1.00) to increase voltage response at low control levels to compensate
for the infrared loss.
0 20406080100
0
20
40
60
80
100
Control Input (%)
Dimmer Output (%)
0 20406080100
0
20
40
60
80
100
Control Input (%)
Dimmer Output (%)
Vista de página 30
1 2 ... 26 27 28 29 30 31 32 33 34 35 36 ... 75 76

Comentários a estes Manuais

Sem comentários